- Chemical Datasheet
Test
procedure
The test was conducted by applying 5 drops of each reagent
on the surface, covered with a watchglass (except those marked
**). Chemicals marked ** were tested saturated cotton wool
ball covered by a bottle. The chemicals were tested over a
period of 24 hours, rinsed off with water and evaluated.
Test
Result - Definition
| NO
EFFECT |
|
No
detectable stain, loss of gloss or change in work surface
material |
| EXCELLENT |
|
Slight
stain or loss of gloss, but no change to the function,
smoothness or life of the work surface material |
| GOOD |
|
A
clearly discernible stain or loss of gloss, but no change
to the function, smoothness or life of the work surface
material |
| FAIR |
|
Unacceptable
staining or discernible deterioration or etching of the
work surface material |
| FAILURE |
|
Severe
staining or moderate deterioration, pitting cratering
or etching of work surface material |
Although
the test was conducted professionally by an independent testing
laboratory*, it is recommended that users conduct their own
tests: convince yourself that TopLabPLUS is the only
true multifunctional worktop!